BONFIGLIOLI Active Cube Instrukcja Obsługi Strona 56

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 94
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 55
56
Motion functions
Motion blocks
The “elemental software unit” of motion control
in Active Cube is the “Motion Block”.
One “Motion Block” completely outlines one
point-to-point positioning step, including:
- target position,
- speed,
- acceleration,
- deceleration,
- ramps,
- delays
Built-in motion control functions allow to combine
up to 32 motion blocks in a conditional sequence,
to program even most sophisticated point-to-point
motion profiles
Position
Pos.2
S4IND
In Pos
Start
Pos
Sequerce
stopped
Motion
Block 5
Motion
Block 2
Motion
Block 1
Power stage
switched off
Pos.1
Pos.5
Speed
Delay 1 Delay 2
Motion Block 1
Delay time 130 ms
Next index delay time 2
Event 1 S4IND
Next index event 1 3
Motion Block 2
Delay time 130 ms
Next index delay time 4
Event 1 S4IND
Next index event 1 5
Motion Block 5
Delay time 0 ms
Next index delay time 0
Event 1 S4IND
Next index event 1 0